Test of lamps and lights according to EN 13032-1

According to UNE EN 13032-4

Asselum has a goniophotometer of type XXX and one of type xxx for the realization of tests of lamps and luminaires according to 13032-1. During the tests, electrical and environmental parameters are constantly monitored to ensure a correct stabilization of the sample under test and to provide the most reliable results possible.

Photometric tests provide the measurement of quantity, colour, quality and spatial distribution of light emitted by lamps, and lights. Our photometric tests also provide other data of interest such as luminous flux, electrical consumption, colour temperature and colour rendering index, among others. All measurements and calculations are compiled in a fully detailed test report.

During the test, environmental conditions are monitored to meet the highest quality standards and provide the most reliable results possible.

We provide the photometric files so you can perform your own simulations.

The test provides the following information:

Photometric parameters

  • Luminous flux of luminaire (lm)

  • Efficiency (lm/W)

  • Position of maximum intensity

  • Lamp power (W)

  • Beam angle

  • Glare index D

  • DLOR

  • Spread-throw angles

  • American roadway classification
    Type

  • ULOR

  • Luminous intensity class G*

  • BUG

Tables and charts

  • Polar intensity diagram

  • Cartesian intensity diagram

  • Utilization factor

  • Intensity matrix

  • Isolux distribution curve

  • Glare

  • Beam or cone angle

  • TM-15 roadway classification

  • Luminaire Classification
    System (LCS)

Color and spectrum parameters

  • Irradiance and Radiance

  • Correlated Color Temperature (CCT)

  • Spectrum 380 nm – 780 nm

  • Color Rendering
    Index (Ra and R1–R14)

  • Chromaticity coordinates
    x,y and u’ v’

  • Angular color uniformity Δu’v’

  • Rf (IES-TM-30)

  • Dominant wavelength

  • CIE 1931 and CIE 1976 diagram

  • S/P Ratio

  • Rg (IES-TM 30)

  • Color purity

  • Du’v’

  • PAR parameters for
    horticulture

  • Índice

Electrical parameters

  • Tension

  • Apparent power

  • Intensity

  • Power factor

  • Electric consumption (W)

  • Reactive power

Additional parameters

  • Environmental conditions

  • Product image

  • Measurement uncertainties

  • Measuring instruments

Do you have any doubts?
Contact us at